1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. SM-A-587932-2

NSN SM-A-587932-2

Circuit Breaker

magnetic blowout arc quenching method, 1.500 inches maximum body length, multipole-single actuator type body style, between pole one and two actuator position designation, trip-reset actuator function.

NSN 5925-00-004-6308 Datasheet

(NSN) National Stock Number
5925-00-004-6308
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-004-6308
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Wed, Jun 7, 1972
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
between pole one and two
Arc Quenching Method
magnetic blowout
Body Length
1.500 inches maximum
Body Style
multipole-single actuator type
Body Width
1.250 inches maximum
Bushing Length
0.380 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width
0.625 inches nominal
Circuit Protection Type
overcurrent all locations
Frequency In Hertz
400.0 all locations
Inclosure Protection Type For Which Designed
hermetically sealed
Internal Trip Release Configuration
relay trip second location
Internal Trip Release Configuration
series trip first location
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Maximum Continuous Load Current Rating Per Pole
3.0 amperes ac and 100.0 milliamperes dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and 500.0 dc all locations
Mounting Facility Type And Quantity
1 threaded bushing
Mounting Surface To Terminal End Distance
1.780 inches maximum
Nominal Thread Size
0.375 inches
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc all locations
Pole Quantity
2
Reset Method
manual
Storage Type
general purpose warehouse
Terminal Type And Quantity
4 wire hook
Thread Quantity Per Inch
32
Thread Series Designator
unef
Trip Delay Time In Seconds Per Rated Continuous Current
0.009 minimum at 150 pct and 0.050 maximum at 150 pct and 0.005 minimum at 200 pct and 0.017 maximum at 200 pct all locations
Trip Release Characteristic
instantaneous and time delay all locations
Trip Release Method
magnetic-hydraulic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Unpackaged Unit Weight
2.100 ounces nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

81541
Sensata Technologies Maryland, Inc
Non-manufacturers
82647
Sensata Technologies, Inc. Div Sensata Attleboro
U.s./canadian manufacturers
80063
Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-004-6308?

    The FSCG of the NSN 5925-00-004-6308 is 5925

  2. Does the NSN 5925-00-004-6308 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-004-6308 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-004-6308 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5925-00-004-6308 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-004-6308 was assigned to the Federal Catalog?

    It was assigned 54 years ago, on Wed, Jun 7, 1972

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.