  4. SYM.2691.2

NSN SYM.2691.2

Rotary Switch

An item generally consisting of one or more turns of tubing or similar material which receives high pressure gas at temperatures above that of the cooling medium and passes latent heat from the refrigerant gas, causing it to liquefy. This item does not include the housing and fan(s).

10.0 amperes resistive load ac at sea level contact load current rating, 125.0 ac at sea level contact voltage rating in volts, breaks before makes each section front contact switching action, tarawa class lha; los angeles class ssn (688); oliver perry class ffg; arliegh burke class ddg; ticonderoga class cg (47); nimitz class cvn; forrestal class cv; wasp class lhd; spruance class dd (963) end item identification, feat criticality code justification.

NSN 5930-00-581-6033 Datasheet

(NSN) National Stock Number
5930-00-581-6033
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-581-6033
Requires Demilitarization
Yes
(INC) Item Name Code
02134
Date
Tue, Jan 1, 1963
Schedule B Code
8536509025
Contact Load Current Rating
10.0 amperes resistive load ac at sea level
Contact Switching Action
breaks before makes each section front
Contact Voltage Rating In Volts
125.0 ac at sea level
Criticality Code Justification
feat
End Item Identification
tarawa class lha; los angeles class ssn (688); oliver perry class ffg; arliegh burke class ddg; ticonderoga class cg (47); nimitz class cvn; forrestal class cv; wasp class lhd; spruance class dd (963)
Features Provided
actuator knob and metallic inclosure
Hazardous Locations/Environmental Protection
watertight
Individual Section Quantity
15
Knob Manufacturer Code
80064
Knob Manufacturer Part Number
9000s6202-73075pc1
Longest Horizontal Distance Between Mounting Centers
7.875 inches nominal single mounting facility
Longest Vertical Distance Between Mounting Centers
4.125 inches nominal single mounting facility
Mounting Facility Pattern
four position rectangular single mounting facility
Mounting Method
bracket(s) single mounting facility
Nondefinitive Spec/Std Data
2jrbb style
Overall Height
19.125 inches nominal
Overall Width
6.312 inches nominal
Shaft Length
1.094 inches nominal single actuator
Shaft Type
rectangular/square, threaded hole single actuator
Special Features
weapon system essential
Square Shaft Size
0.248 inches nominal single actuator
Switch Actuator Indexing Position Quantity
8 single actuator
Switch Actuator Positioning Increment
45.0 degrees single actuator
Switch Actuator Stop Device Type
adjustable stop single actuator
Switch Contact Basic Design
nonpile-up symmetrical
Terminal Type
tab w/screw
Test Data Document
80064-9s5564l drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Unthreaded Mounting Hole Diameter
0.531 inches nominal single mounting facility

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0002134

Cross Reference

CAGE Codes

03950
Naval Inventory Control Point Mechanicsburg
U.s./canadian manufacturers
88829
Tabet Manufacturing Company, Inc. Dba Tabet Manufacturing Co Inc
U.s./canadian manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)
58475
L-3 Communications Westwood Corporation Dba Nmp Division Div L3 Westwood Corporation
U.s./canadian manufacturers
80064
Naval Ship Systems Command
U.s./canadian manufacturers
44291
U.s. Pioneer, L.l.c.
U.s./canadian manufacturers
28003
Winchester Industries Inc
U.s./canadian manufacturers
86796
Roflan Associates Inc
U.s./canadian manufacturers
57626
Comsaco, Llc Dba Comsaco Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-50-9025
Description
switches, rotary, rated at over 5 a, for a voltage not exceeding 1,000 volts
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-581-6033?

    The FSCG of the NSN 5930-00-581-6033 is 5930

  2. Does the NSN 5930-00-581-6033 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509025

  3. Does NSN 5930-00-581-6033 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-00-581-6033 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5930-00-581-6033 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-581-6033 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.