NSN SYSMEX 1000 W/PRINTER

Blood Cell Analyzer-Counter

A definite continuous length of cable,special purpose,electrical, having one or more ends processed or terminated in fittings which provide for connectionn to other items. For items which the rated working is 300 volts or more, see: cable assembly,power,electrical. Excludes items having branches or forks. Excludes: lead,test and cable and conduit assembly,electrical.

automatic,8-parameter; 115/230 volts,50/60 hz ac; determines,white blood,red blood counts,hemoglobin,hematocrit,mean corpuscular volume,mean corpuscular hemoglobin,mean corpuscular hemoglobin concentration,platelet count; shall have a 100 ul whole blood sample; temperature range of 15 to 30 deg cel w/r.h. from 10 to 90 percent; dual probe assy; digital display; contains a printer and data interface port; requisitioner shall specify if analyzer shall include the capability of 3 port differential; voltage and frequency; cenprome service controlled; requisition using published customer order list only in accordance w/service/agency instructions; service poc-for info,army med av 343-7403 com 301-663-7403; air force av 343-7487,com 301-663-7487,navy av-343-7117 com 301-663-7117 general characteristics item description, requestor shall specify voltage/frequency required 115 v,60 hz; 115 v,50 hz; 230 v,50 hz; 230 v,60 hz; request also if it shall have the capability to perform 3-part differential,lymphocytes,mononuclear cells and granulocytes,both in percent and absolute numbers; dla120-89-d-8158 departure from cited document, 110.00 pounds exterior container weight, 2.80 cubic feet unit of issue cube, analyzer-counter blood cell 115/230volts 50/60hz ac part name assigned by controlling agency.

NSN 6640-01-305-1158 Datasheet

(NSN) National Stock Number
6640-01-305-1158
(FSC) Federal Supply Classification
6640 - Laboratory Equipment and Supplies
(NIIN) National Item Identification Number
01-305-1158
Requires Demilitarization
Yes
(INC) Item Name Code
77777
Date
Tue, Aug 1, 1989
Departure From Cited Document
requestor shall specify voltage/frequency required 115 v,60 hz; 115 v,50 hz; 230 v,50 hz; 230 v,60 hz; request also if it shall have the capability to perform 3-part differential,lymphocytes,mononuclear cells and granulocytes,both in percent and absolute numbers; dla120-89-d-8158
General Characteristics Item Description
automatic,8-parameter; 115/230 volts,50/60 hz ac; determines,white blood,red blood counts,hemoglobin,hematocrit,mean corpuscular volume,mean corpuscular hemoglobin,mean corpuscular hemoglobin concentration,platelet count; shall have a 100 ul whole blood sample; temperature range of 15 to 30 deg cel w/r.h. from 10 to 90 percent; dual probe assy; digital display; contains a printer and data interface port; requisitioner shall specify if analyzer shall include the capability of 3 port differential; voltage and frequency; cenprome service controlled; requisition using published customer order list only in accordance w/service/agency instructions; service poc-for info,army med av 343-7403 com 301-663-7403; air force av 343-7487,com 301-663-7487,navy av-343-7117 com 301-663-7117
Exterior Container Weight
110.00 pounds
Part Name Assigned By Controlling Agency
analyzer-counter blood cell 115/230volts 50/60hz ac
Unit Of Issue Cube
2.80 cubic feet

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
SMS - Defense logistics agency, enterprise business systems
Pseudo Item Name Code
1020919

Cross Reference

CAGE Codes

99998
Defense Supply Center Richmond Industrial Plant Equipment /dla/
U.s./canadian manufacturers
1GS32
Baxter Healthcare Corp Baxter Scientific Products Div
U.s./canadian manufacturers

Freight Information

Questions & Answers

  1. What is the FSCG of the NSN 6640-01-305-1158?

    The FSCG of the NSN 6640-01-305-1158 is 6640

  2. Does NSN 6640-01-305-1158 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  3. Does NSN 6640-01-305-1158 contain precious materials?

    Item does not contain precious metal.

  4. Does NSN 6640-01-305-1158 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  5. When the NSN 6640-01-305-1158 was assigned to the Federal Catalog?

    It was assigned 37 years ago, on Tue, Aug 1, 1989