Circuit Breaker

trip-reset actuator function, adjustable trip release features provided, overcurrent all locations circuit protection type, rectangular dimensional envelope body style, at pole two actuator position designation.

NSN 5925-01-093-8678 Datasheet

(NSN) National Stock Number
5925-01-093-8678
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-093-8678
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Fri, Apr 25, 1980
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Body Style
rectangular dimensional envelope
Circuit Protection Type
overcurrent all locations
Features Provided
adjustable trip release
Fragility Factor
moderately rugged
Inclosure Protection Type For Which Designed
general purpose
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
15000.0 ac and 15000.0 dc all locations
Mounting Facility Type And Quantity
6 clamp
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac and 250.0 dc all locations
Overall Height
3.375 inches nominal
Overall Length
8.187 inches nominal
Overall Width
4.125 inches nominal
Pole Quantity
3
Reset Method
manual
Special Handling Feature
magnetic
Storage Type
general purpose warehouse
Terminal Type And Quantity
6 tab, solder lug

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

02989
General Electric Company Dba Ge
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-093-8678?

    The FSCG of the NSN 5925-01-093-8678 is 5925

  2. Does the NSN 5925-01-093-8678 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-093-8678 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-093-8678 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-093-8678 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-093-8678 was assigned to the Federal Catalog?

    It was assigned 46 years ago, on Fri, Apr 25, 1980

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.