Rotary Switch

base single mounting facility mounting method, 7 individual section quantity, 28.0 dc at sea level contact voltage rating in volts, makes before breaks each section rear contact switching action, 5.0 amperes resistive load dc at sea level contact load current rating.

NSN 5930-00-738-2296 Datasheet

(NSN) National Stock Number
5930-00-738-2296
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-738-2296
Requires Demilitarization
Yes
(INC) Item Name Code
02134
Date
Tue, Jan 1, 1963
Schedule B Code
8536509020
Contact Load Current Rating
5.0 amperes resistive load dc at sea level
Contact Switching Action
makes before breaks each section rear
Contact Voltage Rating In Volts
28.0 dc at sea level
Individual Section Quantity
7
Mounting Method
base single mounting facility
Overall Height
2.370 inches nominal
Overall Length
9.250 inches nominal
Overall Width
2.000 inches nominal
Pole Quantity
1 each section rear
Shaft Diameter
0.250 inches nominal single actuator
Shaft Type
round single actuator
Shaft Length
0.620 inches nominal single actuator
Style Designator
tap, square frame
Switch Actuator Indexing Position Quantity
20 single actuator
Switch Actuator Positioning Increment
18.0 degrees single actuator
Switch Actuator Stop Device Type
fixed-adjustable stops single actuator
Switch Contact Basic Design
nonpile-up symmetrical
Terminal Type
tab, solder lug
Throw Quantity
20 each section rear

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0002134

Cross Reference

CAGE Codes

79500
Westinghouse Electric Corp
U.s./canadian manufacturers
97942
Northrop Grumman Systems Corporation Dba Northrop Grumman Systems Corp Div Northrop Grumman Systems Corporation Electronic Systems
U.s./canadian manufacturers
83332
Tech Logistics, Inc.
U.s./canadian manufacturers

Freight Information

Schedule B & Trade

Schedule B
8536-50-9020
Description
switches, rotary, rated at not over 5 a, for a voltage not exceeding 1,000 v
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-738-2296?

    The FSCG of the NSN 5930-00-738-2296 is 5930

  2. Does the NSN 5930-00-738-2296 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509020

  3. Does NSN 5930-00-738-2296 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-00-738-2296 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 5930-00-738-2296 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-738-2296 was assigned to the Federal Catalog?

    It was assigned 63 years ago, on Tue, Jan 1, 1963

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.