NSN VK35

Dial Indicating Hygrometer

A relay that performs the function of opening or closing an electrical circuit in response to electrical changes in an external circuit. In lieu of separable contacts and their actuator(s), the switching function is accomplished by means of an arrangement of semiconductors and passive circuit devices. The device is designed to have electrical isolation between control circuit and output circuit. Excludes:relay,hybrid.

range:m80.0 to p20.0 deg. c dew point;oper. temp.:m10.0 to p55.0 deg c;output signal:0 to 100mv dc;probe input voltage:1 volt;pressure rating:to 5000 psi;flow rate:to 2000 cm/sec in gases,5 cm/sec in liquids;probe mountableup to 3000 ft. from console special features, dial indicating unit type.

NSN 6685-01-066-1317 Datasheet

(NSN) National Stock Number
6685-01-066-1317
(NIIN) National Item Identification Number
01-066-1317
Requires Demilitarization
Yes
(INC) Item Name Code
16515
Date
Sun, Oct 1, 1978
Schedule B Code
9027502000
Special Features
range:m80.0 to p20.0 deg. c dew point;oper. temp.:m10.0 to p55.0 deg c;output signal:0 to 100mv dc;probe input voltage:1 volt;pressure rating:to 5000 psi;flow rate:to 2000 cm/sec in gases,5 cm/sec in liquids;probe mountableup to 3000 ft. from console
Unit Type
dial indicating

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0016515

Cross Reference

CAGE Codes

54502
Ondyne Inc
U.s./canadian manufacturers

Freight Information

Air Commodity
VQ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
F - 150.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
3 - Electrostatic sensitive device (esd)
Uniform Freight Classification Item Number
33170
Water Commodity
652 - Instruments, scientific
National Motor Freight Classification Item Number
058240

Schedule B & Trade

Schedule B
9027-50-2000
Description
thermal analysis instruments and apparatus
End Use
21600 - Laboratory testing instruments
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87445
(NAICS) North American Industrial Classification System
334516

Questions & Answers

  1. What is the FSCG of the NSN 6685-01-066-1317?

    The FSCG of the NSN 6685-01-066-1317 is 6685

  2. Does the NSN 6685-01-066-1317 have a Schedule B code assigned?

    Yes, the Schedule B code is 9027502000

  3. Does NSN 6685-01-066-1317 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6685-01-066-1317 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 6685-01-066-1317 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6685-01-066-1317 was assigned to the Federal Catalog?

    It was assigned 48 years ago, on Sun, Oct 1, 1978

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History