Request Pricing & Availability

NSN: 5925-00-004-6308
Part Number(s):
Quantity:
Company:
Name & Email:
Phone:
Order Terms | Privacy Policy    

NSN 5925-00-004-6308 Circuit Breaker

Manufacturer Part Numbers

Part Number Name Cage Code
SM-A-587932-2 Circuit Breaker 80063
AP14-1769-1 Circuit Breaker 81541

Management Codes

CTL: 9B----- (MOE: DN), 15B2--- (MOE: DM)
SOS: SMS
AAC: Not stocked, centrally procured # (non-stocked items). imm/service centrally managed but not stocked item. procurement will be initiated only after receipt of a requisition.
CIIC:
RC:
QUP: 1
UI: EA
SLC: 0

Freight Codes

NMF Desc: Circuit Breaker/switch Noi
NMFC: 061300
UFC: 34410
LTL: 77.5
LCL:
WCC: Electrical appliances, small
TCC: No special type of cargo code applicable
SHC: Other or no special handling required (sh)
ADC: Shipment is not a consolidation and does not exceed 84 inches in any dimension.
ACC: Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps)
ASH: No special handling required.

Identification

DEMIL Code: A
DEMIL Integ:
ADPE: )
CRITL: X
ENAC:
ESD: )
HMIC: P
Schedule B: 8536200040 – Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
NIIN: 000046308

Technical Characteristics

Actuator Function: Trip-reset
Actuator Position Designation: Between pole one and two
Body Length: 1.500 inches maximum
Body Style: Multipole-single actuator type
Body Width: 1.250 inches maximum
Bushing Length: 0.380 inches maximum
Case Material: Metal
Center To Center Distance Between Terminals Parallel To Length: 0.875 inches nominal
Center To Center Distance Between Terminals Parallel To Width: 0.625 inches nominal
Circuit Protection Type: Overcurrent all locations
Frequency In Hertz: 400.0 all locations
Arc Quenching Method: Magnetic blowout
Maximum Continuous Load Current Rating Per Pole: 3.0 amperes ac all locations and 100.0 milliamperes dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps: 300.0 ac all locations and 500.0 dc all locations
Mounting Facility Type And Quantity: 1 threaded bushing
Mounting Surface To Terminal End Distance: 1.780 inches maximum
Nominal Thread Size: 0.375 inches
Operating Voltage Type And Rating Per Pole In Volts: 240.0 ac all locations and 50.0 dc all locations
Storage Type: General purpose warehouse
Inclosure Protection Type For Which Designed: Hermetically sealed
Internal Trip Release Configuration: Relay trip second location
Internal Trip Release Configuration: Series trip first location
Main Contact Tripping Mechanism Type: Trip free
Manual Actuator Type And Quantity: 1 toggle
Reset Method: Manual
Pole Quantity: 2
Terminal Type And Quantity: 4 wire hook
Thread Quantity Per Inch: 32
Thread Series Designator: Unef
Trip Delay Time In Seconds Per Rated Continuous Current: 0.009 minimum at 150 pct all locations and 0.050 maximum at 150 pct all locations and 0.005 minimum at 200 pct all locations and 0.017 maximum at 200 pct all locations
Trip Release Characteristic: Instantaneous all locations and time delay all locations
Trip Release Method: Magnetic-hydraulic all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent: 115.0 all locations
Unpackaged Unit Weight: 2.100 ounces

Questions & Answers

What are the historical prices recorded for this stock number?
No pre-dated pricing for this NSN could be found.
What NATO entities are users of this NSN?
No recorded entities for this stock number.
How is national stock number 5925-00-004-6308 categorized?
A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Does this item require Demilitarization?
Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9).
Is this item ITAR controlled?
No. This item is not ITAR Controlled.
When was this national stock number assigned to the federal catalog?
Jun 07, 1972