1. Home /
  2. FSC NSN Catalog /
  3. Laboratory Equipment and Supplies /
  4. 13470-062

NSN 13470-062

Electric Liquid Bath

An externally threaded fastener whose threaded portion is of one nominal diameter, no. 10 (0.190 in.) (5 mm) or larger. It is designed with an internal socket or internal multiple spline for use with an internal driver. The head is beveled (conical) or cylindrical in shape. Items with cylindrical shaped heads must have an externally relieved body. A locking feature may be incorporated in the design of the head or threads. See also screw, cap, socket head. Excludes:setscrew; screw, shoulder; bolt, shoulder; screw, externally relieved body; bolt, externally relieved body; and screw, machine.

one 20-100 deg c thermometer and holder,one diffuser shelf,four detachable diffuser shelf legs accessory components and quantity, not included agitator, -0.1 to 0.1 deg celsius accuracy range, not included cooling coils for below room temp use, not included constant water level attachment.

NSN 6640-01-045-9164 Datasheet

(NSN) National Stock Number
6640-01-045-9164
(FSC) Federal Supply Classification
6640 - Laboratory Equipment and Supplies
(NIIN) National Item Identification Number
01-045-9164
Requires Demilitarization
Yes
(INC) Item Name Code
20327
Date
Tue, Aug 9, 1977
Schedule B Code
9018908000
Accessory Components And Quantity
one 20-100 deg c thermometer and holder,one diffuser shelf,four detachable diffuser shelf legs
Accuracy Range
-0.1 to 0.1 deg celsius
Agitator
not included
Constant Water Level Attachment
not included
Cooling Coils For Below Room Temp Use
not included
Heating Element Current Type
ac
Heating Element Quantity
2
Heating Element Frequency Rating
50.0 hertz nominal or 60.0 hertz nominal
Heating Element Phase
single
Heating Element Type
electric immersion
Heating Element Voltage Rating
115.0 volts nominal
Heating Element Wattage In Watts
750.0 and 1000.0
Inside Depth
7.000 inches nominal
Inside Length
27.000 inches nominal
Inside Width
10.500 inches nominal
Insulated Feature
included
Low Water Cutoff
not included
Pilot Light
included
Material
steel corrosion resisting reservoir
Opening Quantity
1
Operating Temp Range
+60.0 to 100.0 celsius
Reservoir Removability
nonremovable
Shape
rectangular
Special Features
diffuser shelf adjustable from 5 in. to 7 in. depth
Temp Regulating Settings
60 deg c,100 deg c
Test Tube Rack
not included
Thermometer Opening
provided
Thermoregulator
included

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
U - Precious metal content is unknown
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9M - Defense supply center philadelphia directorate of medical materiel philadelphia, pennsylvania 19111
Pseudo Item Name Code
0020327

Cross Reference

CAGE Codes

65662
Vwr Scientific Inc
U.s./canadian manufacturers

Freight Information

Schedule B & Trade

Schedule B
9018-90-8000
Description
instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87229
(NAICS) North American Industrial Classification System
339112

Questions & Answers

  1. What is the FSCG of the NSN 6640-01-045-9164?

    The FSCG of the NSN 6640-01-045-9164 is 6640

  2. Does the NSN 6640-01-045-9164 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018908000

  3. Does NSN 6640-01-045-9164 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6640-01-045-9164 contain precious materials?

    Precious metal content is unknown

  5. Does NSN 6640-01-045-9164 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 6640-01-045-9164 was assigned to the Federal Catalog?

    It was assigned 49 years ago, on Tue, Aug 9, 1977

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 9 hours ago
View History