Circuit Breaker

Model / MPN: 13MC1-104-10 | NSN: 5925-00-814-2187
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-00-814-2187
Sold in multiples of
1 EA
DEMIL
NO
Thread Pitch Diameters
+0.1177/+0.1214 inches
Body Style
Multipole-multiple actuator type
Body Length
2.530 inches
Body Width
2.228 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.940 inches
Center To Center Distance Between Terminals Parallel To Width
0.750 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.060 inches
Switch Contact Arrangement
Single pole, double throw
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
0.750 inches
Boss Height
0.150 inches
Mounting Surface To Terminal End Distance
2.480 inches
Pole Quantity
3
Mounting Facility Type And Quantity
6 threaded hole
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
10.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 all locations
Ultimate Trip Time Per Pole In Seconds
18.000 all locations and 70.000 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
3 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At each pole
External Actuator Linkage Arrangement
One, two, and three linked
Auxiliary Switch Function And Quantity
1 control
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.138 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
4.000 at 200 pct all locations and 10.000 at 200 pct all locations
Inclosure Protection Type For Which Designed
Explosion resistant and fungus resistant and moisture resistant
Switch Terminal Type
Tab w/screw
Switch Current Rating And Type In Amps
5.0 ac and 1.0 dc
Switch Voltage Rating And Type In Volts
125.0 ac and 50.0 dc
Frequency In Hertz
60.0 all locations
Thread Series Designator
Unc
Terminal Type And Quantity
6 threaded stud

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
13MC1-104-10 Cross Reference
  • 128C188H06
  • APL111-1CR
  • AM333HKMG6-10-250VAC60C4