Power Transformer

Model / MPN: 153C258A01 | NSN: 5950-01-339-6685
ITAR Registered seal

A transformer consisting of one or more primary windin (s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1) , pulse.

Product Details
NATO Stock Number
5950-01-339-6685
Sold in multiples of
EA
DEMIL
NO
Reliability Indicator
Not established
Hazardous Locations/environmental Protection
Vibration resistant
Overall Length
5.060 inches
Center To Center Distance Between Mounting Facilities Parallel To Length
3.990 inches single mounting facility single center group and 4.010 inches single mounting facility single center group
Center To Center Distance Between Mounting Facilities Parallel To Width
2.240 inches single mounting facility single center group and 2.260 inches single mounting facility single center group
Overall Height
4.620 inches
Overall Width
4.250 inches
Frequency Rating
10.0 kilohertz single component
Input-output Phase Relationship
Single phase to single phase single component
Maximum Operating Temp
155.0 degrees celsius
Inclosure Type
Fully enclosed
Mounting Facility Quantity
4 single group
Mounting Method
Threaded hole single group
Winding Function And Quantity
3 primary single component and 1 secondary single component
Thread Size
0.190 inches single group
Winding Operating Current
127.26 amperes ac single component single secondary
Winding Operating Current
14.14 amperes ac single component all primary
Winding Power Rating
1.844 kilovolt-amperes single component single secondary
Winding Operating Voltage
118.07 ac volts single component all primary
Winding Operating Voltage
49.49 ac volts single component single secondary
Test Data Document
97942-153c258 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unf single group
Terminal Type And Quantity
7 tab, solder lug and 1 solderless lug

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
153C258A01 Cross Reference