Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Circuit Breaker

Model / MPN: 17001-03 | NSN: 5925-01-213-6397
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-01-213-6397
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Single pole type
Bushing Length
0.468 inches
Body Length
1.375 inches
Body Width
0.680 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.125 inches
Nonturn Device Location
At 12 oclock
Nonturn Device Radius
0.222 inches
Nonturn Device Width
0.028 inches
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
1.702 inches
Pole Quantity
1
Arc Quenching Method
Deion
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac and 15.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac and 50.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac and 1000.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
138.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.500 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.100 at 200 pct and 2.000 at 200 pct single location
Inclosure Protection Type For Which Designed
General purpose
Frequency In Hertz
50.0 or 60.0 single location
Thread Series Designator
Uns
Terminal Type And Quantity
2 quick disconnect, male

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
17001-03 Cross Reference
  • T11-1-15.00A-01-
  • T11-1-15.00A-01-11AL
  • 17001-03