1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. 2110-0339

NSN 2110-0339

Circuit Breaker

magnetic blowout arc quenching method, at pole one actuator position designation, 2.990 inches minimum and 3.010 inches maximum body length, trip-reset actuator function, 2.570 inches minimum and 2.590 inches maximum body height.

NSN 5925-01-042-0109 Datasheet

(NSN) National Stock Number
5925-01-042-0109
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-042-0109
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Mon, Jun 6, 1977
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Arc Quenching Method
magnetic blowout
Body Height
2.570 inches minimum and 2.590 inches maximum
Body Length
2.990 inches minimum and 3.010 inches maximum
Body Style
single pole type
Body Width
0.720 inches minimum and 0.740 inches maximum
Boss Height
0.240 inches minimum and 0.260 inches maximum
Circuit Protection Type
overcurrent single location
Fragility Factor
moderately rugged
Frequency In Hertz
60.0 single location
Inclosure Protection Type For Which Designed
dustproof
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
10000.0 ac single location
Mounting Facility Type And Quantity
2 terminal
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac single location
Pole Quantity
1
Reset Method
manual
Specification/Standard Data
81348-w-c-375/1 government specification
Storage Type
general purpose warehouse
Terminal Type And Quantity
1 clip and 1 screw
Test Data Document
"81348-w-c-375 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Trip Release Ambient Temp Rating
25.0 celsius nominal single location
Trip Release Characteristic
time delay single location
Trip Release Method
thermal-magnetic single location
Trip Delay Time In Seconds Per Rated Continuous Current
120.000 maximum at 200 pct single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

28480
Hewlett-Packard Company Dba Hp
U.s./canadian manufacturers
95105
Rockwell Collins, Inc. Div Collins Aerospace - Mission Systems
U.s./canadian manufacturers
56365
Schneider Electric Usa, Inc.
U.s./canadian manufacturers
81348
Federal Specifications Promulgated by General Services Administration Washington Dc
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-042-0109?

    The FSCG of the NSN 5925-01-042-0109 is 5925

  2. Does the NSN 5925-01-042-0109 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-042-0109 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-042-0109 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-042-0109 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-042-0109 was assigned to the Federal Catalog?

    It was assigned 49 years ago, on Mon, Jun 6, 1977

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 9 hours ago
View History