Circuit Breaker

Model / MPN: 3105-0084 | NSN: 5925-01-144-4906
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-01-144-4906
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Single pole type
Bushing Length
0.400 inches
Body Length
1.140 inches
Body Width
0.570 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
1.000 inches
End Application
3964a; teletype, model 28
Mounting Surface To Terminal End Distance
2.272 inches
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
27
Maximum Continuous Load Current Rating Per Pole
1.2 amperes ac single location and 1.2 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 24.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
12.0 ac single location and 12.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
Reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Shunt trip single location
Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
10.000 at 200 pct single location and 40.000 at 200 pct single location
Inclosure Protection Type For Which Designed
Fungus resistant
Trip Release Ambient Tempurature Rating
70.0 degrees fahrenheit single location
Frequency In Hertz
60.0 single location
Thread Series Designator
Uns
Terminal Type And Quantity
3 quick disconnect, male

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
3105-0084 Cross Reference
  • 45700PA311211-2A
  • 45-700-P-A3-1.2A
  • 3105-0084