1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. 420433

NSN 420433

Circuit Breaker

An externally threaded fastener whose threaded portion is of one nominal diameter, no 0 (0.060 in./1.5 mm) or larger, designed to be held or driven with either a wrench or an inserted driver or both (excluding internal socket or internal multiple spline types), in sizes below no. 10 (0.190 in./5 mm). No. 10 and larger sizes must have a head designed for any type inserted driver (excluding internal socket or internal multiple spline types), but may also be designed for external wrenching. A locking feature may be incorporated in the design of the head or threads. Excludes:bolt, clevis; bolt, externally relieved body; screw, externally relieved body; and screw, assembled washer. See also, screw, instrument; bolt, machine; bolt, internal wrenching; and screw, cap socket head.

trip-resettrip-reset actuator function, single pole typesingle pole type body style, 2.480 inches minimum and 2.480 inches minimum and 2.500 inches maximum2.500 inches maximum body length, at pole oneat pole one actuator position designation, magnetic blowoutmagnetic blowout arc quenching method.

NSN 5925-00-271-1690 Datasheet

(NSN) National Stock Number
5925-00-271-1690
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-271-1690
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Sat, Jul 28, 1973
Schedule B Code
8536200040
Actuator Function
trip-resettrip-reset
Actuator Position Designation
at pole oneat pole one
Arc Quenching Method
magnetic blowoutmagnetic blowout
Body Length
2.480 inches minimum and 2.480 inches minimum and 2.500 inches maximum2.500 inches maximum
Body Style
single pole typesingle pole type
Body Width
0.750 inches maximum0.750 inches maximum
Boss Height
0.150 inches nominal0.150 inches nominal
Center To Center Distance Between Terminals Parallel To Length
1.940 inches nominal1.940 inches nominal
Circuit Protection Type
overcurrent single locationovercurrent single location
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
2.050 inches minimum and 2.050 inches minimum and 2.070 inches maximum2.070 inches maximum
Fragility Factor
moderately ruggedmoderately rugged
Frequency In Hertz
400.0 single location400.0 single location
Inclosure Protection Type For Which Designed
moisture resistant and moisture resistant and shock resistant and shock resistant and vibration resistantvibration resistant
Internal Trip Release Configuration
series trip single locationseries trip single location
Main Contact Tripping Mechanism Type
trip freetrip free
Manual Actuator Type And Quantity
1 toggle1 toggle
Material
plastic caseplastic case
Maximum Continuous Load Current Rating Per Pole
20.0 amperes ac single location20.0 amperes ac single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac single location1000.0 ac single location
Mounting Facility Type And Quantity
2 threaded hole(s)2 threaded hole(s)
Mounting Surface To Terminal End Distance
2.475 inches nominal2.475 inches nominal
Nominal Thread Size
0.138 inches0.138 inches
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location250.0 ac single location
Pole Quantity
11
Reset Method
manualmanual
Special Handling Feature
magneticmagnetic
Specification/Standard Data
81349-mil-c-55629/1 government specification81349-mil-c-55629/1 government specification
Storage Type
general purpose warehousegeneral purpose warehouse
Terminal Type And Quantity
2 threaded stud2 threaded stud
Test Data Document
"81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.).81349-mil-c-55629 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Pitch Diameters
+0.1177 to 0.1214 inches+0.1177 to 0.1214 inches
Thread Quantity Per Inch
3232
Thread Series Designator
unified national coarse (unc)unified national coarse (unc)
Trip Delay Time In Seconds Per Rated Continuous Current
9.500 minimum at 200 pct and 9.500 minimum at 200 pct and 150.000 maximum at 200 pct single location150.000 maximum at 200 pct single location
Trip Release Characteristic
time delay single locationtime delay single location
Trip Release Method
magnetic single locationmagnetic single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location150.0 single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
SMS - Defense logistics agency, enterprise business systems
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

79405
Wood Electric Operations Potter and Brumfield Div Amf Inc
U.s./canadian manufacturers
36378
Raytheon Technical Services Company
U.s./canadian manufacturers
82647
Sensata Technologies, Inc. Div Sensata Attleboro
U.s./canadian manufacturers
74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers
81541
Sensata Technologies Maryland, Inc
Non-manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-271-1690?

    The FSCG of the NSN 5925-00-271-1690 is 5925

  2. Does the NSN 5925-00-271-1690 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-271-1690 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-271-1690 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-00-271-1690 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-271-1690 was assigned to the Federal Catalog?

    It was assigned 53 years ago, on Sat, Jul 28, 1973

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 11 hours ago
View History