NATO Stock Number
5915-01-395-9814
Sold in multiples of
EA
DEMIL
DEMIL/MLI
Overall Length
Between 1.802 inches and 1.823 inches
Overall Height
2.338 inches
Overall Width
Between 1.802 inches and 1.823 inches
Mounting Slot Width
Between 0.148 inches and 0.164 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
1.500 inches
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
1.500 inches
Operating Tempurature Range
-55.0/+125.0 degrees celsius
Source Impedance Rating Per Function
50.0 ohms 1st radio interference
Source Impedance Rating Per Function
50.0 ohms 2nd radio interference
Source Impedance Rating Per Function
50.0 ohms 5th radio interference
Source Impedance Rating Per Function
50.0 ohms 6th radio interference
Source Impedance Rating Per Function
50.0 ohms 3rd radio interference
Source Impedance Rating Per Function
50.0 ohms 4th radio interference
Load Impedance Per Function
50.0 ohms 1st radio interference
Load Impedance Per Function
50.0 ohms 3rd radio interference
Load Impedance Per Function
50.0 ohms 2nd radio interference
Load Impedance Per Function
50.0 ohms 6th radio interference
Load Impedance Per Function
50.0 ohms 4th radio interference
Load Impedance Per Function
50.0 ohms 5th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 1st radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 2nd radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 3rd radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 4th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 5th radio interference
Power Line Frequency Rating Per Function In Hertz
400.0 6th radio interference
Operating Current Rating Per Function In Amps
13.0 2nd radio interference
Operating Current Rating Per Function In Amps
13.0 3rd radio interference
Operating Current Rating Per Function In Amps
13.0 1st radio interference
Operating Current Rating Per Function In Amps
13.0 4th radio interference
Operating Current Rating Per Function In Amps
13.0 5th radio interference
Operating Current Rating Per Function In Amps
13.0 6th radio interference
Full Load Insertion Loss Frequencies In Megahertz
10.0 and 100.0
Full Load Minimum Insertion Loss At Specificationified Frequency In Decibels
8.0 and 44.0
Inclosure Type
Encased
Mounting Facility Type And Quantity
4 slot
Features Provided
Corrosion resistant
Functional Terminal Type And Quantity
37 friction w/grounding strap and pin input-output
Operating Voltage Rating And Type Per Function
115.0 volts ac 1st radio interference 1st function and 320.0 volts dc 1st radio interference 1st function
Operating Voltage Rating And Type Per Function
115.0 volts ac 2nd radio interference 2nd function and 320.0 volts dc 2nd radio interference 2nd function
Operating Voltage Rating And Type Per Function
115.0 volts ac 3rd radio interference 3rd function and 320.0 volts dc 3rd radio interference 3rd function
Operating Voltage Rating And Type Per Function
115.0 volts ac 4th radio interference 4th function and 320.0 volts dc 4th radio interference 4th function
Operating Voltage Rating And Type Per Function
115.0 volts ac 6th radio interference 6th function and 320.0 volts dc 6th radio interference 6th function
Operating Voltage Rating And Type Per Function
115.0 volts ac 5th radio interference 5th function and 320.0 volts dc 5th radio interference 5th function
Body Material
Aluminum
Maximum Dielectric Withstanding Dc Voltage
800.0 volts at altitude
Precious Material And Location
Contact surfaces gold
Precious Material
Gold
Style Designator
Filter connector