Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Circuit Breaker

Model / MPN: 7727-6-4 | NSN: 5925-00-542-6457
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-00-542-6457
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Single pole type
Bushing Length
0.359 inches
Body Length
0.750 inches
Body Width
0.562 inches
Case Material
Metal
Center To Center Distance Between Terminals Parallel To Length
0.593 inches
Switch Contact Arrangement
Single pole, single throw, normally open
Fragility Factor
Moderately rugged
Mounting Surface To Terminal End Distance
1.420 inches
Pole Quantity
1
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
32
Maximum Continuous Load Current Rating Per Pole
4.0 amperes ac single location
Operating Voltage Type And Rating Per Pole In Volts
120.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
2500.0 ac all locations
Circuit Protection Type
Overcurrent single location
Trip Release Method
Thermal all locations
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
150.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push button
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Auxiliary Switch Function And Quantity
1 alarm
Internal Trip Release Configuration
Series trip all locations
Thread Size
0.438 inches
Switch Location And Position Designation
Internal at pole one
Trip Delay Time In Seconds Per Rated Continuous Current
2.000 at 200 pct all locations and 35.000 at 200 pct all locations
Inclosure Protection Type For Which Designed
Vibration resistant and humidity proof
Trip Release Ambient Tempurature Rating
25.0 degrees celsius single location
Switch Current Rating And Type In Amps
5.0 dc
Switch Voltage Rating And Type In Volts
28.0 dc
Frequency In Hertz
400.0 single location
Unpackaged Unit Weight
1.000 ounces
Thread Series Designator
Uns
Terminal Type And Quantity
2 tab w/screw

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
7727-6-4 Cross Reference
  • 3150240-901-1
  • 7277-2-4
  • 7277-1-4