Power Transformer

Model / MPN: 780771 | NSN: 5950-01-208-5118
ITAR Registered seal

A transformer consisting of one or more primary windin (s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes transformer (1) , pulse.

Product Details
NATO Stock Number
5950-01-208-5118
Sold in multiples of
EA
DEMIL
NO
Reliability Indicator
Not established
Overall Length
2.410 inches
Overall Width
Between 1.660 inches and 1.740 inches
Mounting Hole Diameter
0.183 inches and 0.193 inches single group
Frequency Rating
380.0 hertz and 420.0 hertz single component
Input-output Phase Relationship
Single phase to single phase single component
Winding Shielding Method
Internal shield brought out to terminal single component
Body Height
1.420 inches
Maximum Operating Temp
170.0 degrees celsius
Distance Between Mounting Facility Centers
1.990 inches and 2.010 inches single mounting facility single center group
Inclosure Type
Fully enclosed
Mounting Facility Quantity
2 single group
Mounting Method
Unthreaded hole single group
Winding Function And Quantity
1 primary and 2 secondary single component
Winding Operating Current
120.0 milliamperes ac single component single primary
Winding Operating Current
180.0 milliamperes ac single component 1st secondary
Winding Operating Current
380.0 milliamperes ac single component 2nd secondary
Winding Operating Voltage
204.00 ac volts and 248.00 ac volts single component single primary
Winding Operating Voltage
19.50 ac volts single component 1st secondary
Winding Operating Voltage
35.00 ac volts single component 2nd secondary
Terminal Type And Quantity
9 pin

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
780771 Cross Reference
  • PEI 5976