NATO Stock Number
5925-00-866-2960
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Single pole type
Bushing Length
Between 0.365 inches and 0.385 inches
Body Length
1.375 inches
Body Width
0.687 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Length
Between 1.010 inches and 1.030 inches
Mounting Surface To Terminal End Distance
2.035 inches
Pole Quantity
1
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
1 threaded bushing
Storage Type
General purpose warehouse
Thready Qty Per Inch (tpi)
24
Maximum Continuous Load Current Rating Per Pole
1.0 amperes ac single location and 1.0 amperes dc single location
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac single location and 32.0 dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
100.0 ac single location and 150.0 dc single location
Circuit Protection Type
Overcurrent single location
Trip Release Method
Magnetic single location
Trip Release Characteristic
Time delay single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
135.0 single location
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 push-pull
Actuator Function
Trip-reset
Actuator Position Designation
At pole one
Internal Trip Release Configuration
Series trip single location
Thread Size
0.375 inches
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct single location and 1.800 at 200 pct single location
Inclosure Protection Type For Which Designed
Shock resistant and vibration resistant
Frequency In Hertz
400.0 single location
Test Data Document
98571-830823 drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing)
Thread Series Designator
Unf
Terminal Type And Quantity
2 tab w/screw