NATO Stock Number
5930-00-324-0416
Sold in multiples of
1 EA
DEMIL
NO
Thread Class
2a single mounting facility
Thread Length
0.340 inches single mounting facility
Hazardous Locations/environmental Protection
Explosion proof
Overall Length
2.460 inches
First Flat Length
0.560 inches single actuator
Flat Height
0.215 inches single actuator and 0.221 inches single actuator
Shaft Diameter
0.248 inches single actuator and 0.251 inches single actuator
Shaft Length
0.900 inches single actuator
Overall Diameter
1.100 inches
Individual Section Quantity
2
Operating Tempurature Range
-54.0/+71.0 degrees celsius
Switch Contact Basic Design
Nonpile-up symmetrical
Pole Quantity
2 each section front
Throw Quantity
5 each section rear
Mounting Method
Threaded bushing w/panel seal single mounting facility
Thread Size
0.375 inches single mounting facility
Contact Voltage Rating In Volts
115.0 ac at sea level
Contact Voltage Rating In Volts
28.0 dc at sea level
Shaft Flat/slot Angular Location
180.0 degrees from contact position 1 single actuator
Rotor Through Connection Quantity
2 each section
Switch Actuator Indexing Position Quantity
5 single actuator
Shaft Type
Round, flatted single actuator
Terminal Type
Tab, solder lug
Contact Switching Action
Breaks before makes each section rear
Switch Actuator Positioning Increment
30.0 degrees single actuator
Detent Rotational Torque Range
+1.500/+3.000 inch-pounds single actuator
Switch Actuator Stop Device Type
Fixed stop single actuator
Contact Load Current Rating
200.0 milliamperes resistive load ac at sea level
Contact Load Current Rating
200.0 milliamperes resistive load dc at sea level and 100.0 milliamperes inductive load dc at sea level
Style Designator
Tap, circular, bushing mount
Test Data Document
81349-mil-s-3786 specification (includes engineering type bulletins, brochures, etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "", etc.).
Thread Series Designator
Unef single mounting facility