1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. AP11-1048-2

NSN AP11-1048-2

Circuit Breaker

An item designed to suppress undesired (interfering) frequencies and have a minimal effect on the desired frequencies when inserted in an electrical power circuit. Excludes:items which consist of a single capacitor, inductor, resistor, or devices consisting of only two or more circuit elements of the same basic name. Excludes:filter, low pass and suppressor, ignition interference. For items designed to be inserted in a line which is primarily intended to carry high frequency waves modulated with signals, such as antenna lead-in, see filter, band suppression and filter, band pass. See also limiter, electrical noise.

multipole-single actuator type body style, trip-reset actuator function, at pole two actuator position designation, magnetic blowout arc quenching method, 1.562 inches maximum body length.

NSN 5925-01-044-0307 Datasheet

(NSN) National Stock Number
5925-01-044-0307
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-044-0307
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Tue, Jul 5, 1977
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole two
Arc Quenching Method
magnetic blowout
Body Length
1.562 inches maximum
Body Style
multipole-single actuator type
Body Width
1.937 inches maximum
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Center To Center Distance Between Terminals Parallel To Width
0.594 inches minimum and 0.656 inches maximum
Circuit Protection Type
overcurrent all locations
Fragility Factor
moderately rugged
Frequency In Hertz
400.0 all locations
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
Internal Trip Release Configuration
series trip all locations
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Maximum Continuous Load Current Rating Per Pole
2.0 amperes ac and 2.0 amperes dc all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
300.0 ac and 500.0 dc all locations
Mounting Facility Type And Quantity
1 threaded bushing with panel seal
Mounting Surface To Terminal End Distance
1.828 inches maximum
Nominal Thread Size
0.375 inches
Operating Voltage Type And Rating Per Pole In Volts
240.0 ac and 50.0 dc all locations
Pole Quantity
3
Reset Method
manual
Special Handling Feature
magnetic
Specification/Standard Data
81349-mil-c-39019/5 government specification
Storage Type
general purpose warehouse
Terminal Type And Quantity
6 wire hook
Test Data Document
"81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Pitch Diameters
+0.3503 to 0.3537 inches
Thread Quantity Per Inch
32
Thread Series Designator
unef
Trip Release Characteristic
time delay all locations
Trip Release Method
magnetic all locations
Trip Delay Time In Seconds Per Rated Continuous Current
0.550 minimum at 200 pct and 10.000 maximum at 200 pct all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Unpackaged Unit Weight
150.0 grams nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

99380
Sierra Networks Inc Sierracom Div
U.s./canadian manufacturers
96214
Raytheon Company Dba Raytheon
U.s./canadian manufacturers
74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers
81541
Sensata Technologies Maryland, Inc
Non-manufacturers
82227
Vdo Control Systems Inc
U.s./canadian manufacturers
24930
L3harris Technologies, Inc Div Space & Airborne Systems
U.s./canadian manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)
80063
Us Army Communications & Electronics Materiel Readiness Command Logistics Engineering Dir
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
35205
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
063160

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-044-0307?

    The FSCG of the NSN 5925-01-044-0307 is 5925

  2. Does the NSN 5925-01-044-0307 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-044-0307 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-044-0307 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-044-0307 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-044-0307 was assigned to the Federal Catalog?

    It was assigned 49 years ago, on Tue, Jul 5, 1977

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 9 hours ago
View History