1. Home /
  2. FSC NSN Catalog /
  3. Supplies, Equipment and Medical and Surgical Instruments /
  4. CH6067

NSN CH6067

Artery Clamp

A transformer consisting of one or more primary winding(s) and one or more secondary winding(s). It may be designed for direct connection to an alternating current source for purposes of changing the secondary volts and amperes or designed to eliminate metallic interconnection between circuits in an overall one to one voltage ratio, with or without additional output windings, or items designed to automatically maintain a constant output voltage within specified limits under varying input or load conditions. Also includes items having a provision for mechanically changing the turns ratio or inductive coupling in progressive increments by means of voltage taps, ratio adjuster, or devices oe similar design. For transformers having winding(s) common to both input and output circuits, see transformer (1), power, autotransformer. Excludes:transformer (1), pulse.

40.0 millimeters nominal jaw length, adjusting screw action type, glover design designation, serrated and straight jaw type, clamp artery glover 9cm lg serrated straight 40mm jaw lg bulldog part name assigned by controlling agency.

NSN 6515-00-690-3215 Datasheet

(NSN) National Stock Number
6515-00-690-3215
(NIIN) National Item Identification Number
00-690-3215
Requires Demilitarization
Yes
(INC) Item Name Code
26207
Date
Sun, Jan 1, 1961
Schedule B Code
9018908000
Action Type
adjusting screw
Design Designation
glover
Jaw Type
serrated and straight
Jaw Length
40.0 millimeters nominal
Part Name Assigned By Controlling Agency
clamp artery glover 9cm lg serrated straight 40mm jaw lg bulldog
Overall Length
9.0 centimeters nominal
Unit Type
bulldog

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Pseudo Item Name Code
0026207

Cross Reference

CAGE Codes

47258
Pilling Surgical Inc Dba Pilling Weck Div Pilling Instruments
U.s./canadian manufacturers
55187
Sklar Corporation Dba Sklar Instruments
U.s./canadian manufacturers
9C381
Owens & Minor Distribution Inc
Non-manufacturers
054A6
Boss Instruments, Limited Inc
Non-manufacturers
5DKK1
Carefusion 2200 Inc
Non-manufacturers
07TA6
Cardinal Health 200, Llc
U.s./canadian manufacturers

Freight Information

Air Commodity
MZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
W - Rating variable
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
00000
Water Commodity
651 - Instruments, medical and surgical
National Motor Freight Classification Item Number
056590

Schedule B & Trade

Schedule B
9018-90-8000
Description
instruments and appliances used in medical, surgical, dental or veterinary sciences, nesoi
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87229
(NAICS) North American Industrial Classification System
339112

Questions & Answers

  1. What is the FSCG of the NSN 6515-00-690-3215?

    The FSCG of the NSN 6515-00-690-3215 is 6515

  2. Does the NSN 6515-00-690-3215 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018908000

  3. Does NSN 6515-00-690-3215 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6515-00-690-3215 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6515-00-690-3215 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6515-00-690-3215 was assigned to the Federal Catalog?

    It was assigned 65 years ago, on Sun, Jan 1, 1961