Cardiovascul Catheterization Kit

A grouping of two or more physically connected or related electrical an/or electronic parts capable of dissassemblage. Each component of the assemblage must be capable of functioning in accordance with its own item name. Consists of a single printed circuit board or terminal board upon which are mounted separately manufactured electronic components such as capacitors, inductors, resistors, and the like. It may also include printed electronic components. The item is generally part of a subassembly and cannot be assigned a more definite item name. For items having a complete individual electrical/electronic function, use applicable item name such as amplifier (as modified); power supply; or the like. For items not having a complete individual electrical/electronic function, see applicable subassembly name, such as amplifier subassembly; power supply subassembly; or the like. For an assembly of electrical/electronic components mounted on other than a single printed wiring board, see electronic components assembly. Excludes:printed circuit board

disposable disposition after initial use, consist of 18 g x 2-1/2 in (6.35 cm) radiopaque catheter over 20 g introducer needle; 18 g x 2-1/2 in (6.35 cm) thin wall needle; 5 cc syringe spring wire introduction syringe; 0.035 in (0.89 mm) diameter x 23-5/8 in (60 cm) dual purpose marked spring wire guide (straight soft tip on one end,j tip on the other end); pressure transduction probe; vessel dilator; 7 fr x 8 in (20 cm) radiopaque polyurethane multi-lumen indwelling catheter; 3 extension line clamps; catheter clamp; and 3 luer lock injection caps special features, sterile sterility, 5 unit package quantity.

NSN 6515-01-371-2320 Datasheet

(NSN) National Stock Number
6515-01-371-2320
(NIIN) National Item Identification Number
01-371-2320
Requires Demilitarization
Yes
(INC) Item Name Code
45631
Date
Tue, Feb 9, 1993
Schedule B Code
9018390030
Disposition After Initial Use
disposable
Special Features
consist of 18 g x 2-1/2 in (6.35 cm) radiopaque catheter over 20 g introducer needle; 18 g x 2-1/2 in (6.35 cm) thin wall needle; 5 cc syringe spring wire introduction syringe; 0.035 in (0.89 mm) diameter x 23-5/8 in (60 cm) dual purpose marked spring wire guide (straight soft tip on one end,j tip on the other end); pressure transduction probe; vessel dilator; 7 fr x 8 in (20 cm) radiopaque polyurethane multi-lumen indwelling catheter; 3 extension line clamps; catheter clamp; and 3 luer lock injection caps
Sterility
sterile
Unit Package Quantity
5

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
N - Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.
Source of Supply Code
D9M -
Pseudo Item Name Code
0045631

Cross Reference

CAGE Codes

0UFF3
Independent Medical Associates, Inc
Non-manufacturers
60791
Arrow International, Inc. Dba Teleflex
U.s./canadian manufacturers
B6451
Teleflex Medical
Non-manufacturers
U7017
Kimal Plc
Non-us manufacturer (nato), other foreign organization or codification bureaus

Freight Information

Schedule B & Trade

Schedule B
9018-39-0030
Description
bougies, catheters, drains and sondes and parts and accessories
End Use
21610 - Medicinal equipment
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
87221
(NAICS) North American Industrial Classification System
339112

Questions & Answers

  1. What is the FSCG of the NSN 6515-01-371-2320?

    The FSCG of the NSN 6515-01-371-2320 is 6515

  2. Does the NSN 6515-01-371-2320 have a Schedule B code assigned?

    Yes, the Schedule B code is 9018390030

  3. Does NSN 6515-01-371-2320 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 6515-01-371-2320 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 6515-01-371-2320 contain hazardous materials?

    Indicates there is no data in the hmirs and the nsn is in a fsc not generally suspected of containing hazardous materials.

  6. When the NSN 6515-01-371-2320 was assigned to the Federal Catalog?

    It was assigned 33 years ago, on Tue, Feb 9, 1993

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.