Secure Ordering: +1 (757) 528-8028
NationalStockNumber.info
NationalStockNumber.INFO

Worldwide distributor of NSN parts and consumables located in the USA.

Circuit Breaker

Model / MPN: E122150203024 | NSN: 5925-01-097-6617
ITAR Registered seal

A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. May include provisions for manual operation. At least one set of contacts must be in series with the actuating elemen (s). A combination of semiconductor and passive devices may be used in lieu of contacts. For automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). For items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. Excludes circuit breaker box and magneto "breaker" assemblies. See also switch (as modified) ; and controller.

Product Details
NATO Stock Number
5925-01-097-6617
Sold in multiples of
1 EA
DEMIL
NO
Body Style
Multipole-single actuator type
Body Length
Between 1.970 inches and 2.030 inches
Body Width
Between 1.510 inches and 1.570 inches
Body Height
Between 1.740 inches and 1.770 inches
Case Material
Plastic
Center To Center Distance Between Terminals Parallel To Width
Between 0.595 inches and 0.655 inches
Fragility Factor
Moderately rugged
Boss Height
Between 0.095 inches and 0.155 inches
Pole Quantity
2
Arc Quenching Method
Magnetic blowout
Mounting Facility Type And Quantity
2 clip
Storage Type
General purpose warehouse
Maximum Continuous Load Current Rating Per Pole
15.0 amperes ac all locations
Operating Voltage Type And Rating Per Pole In Volts
250.0 ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
1000.0 ac all locations
Circuit Protection Type
Overcurrent all locations
Trip Release Method
Magnetic-hydraulic all locations
Trip Release Characteristic
Time delay all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
125.0 all locations
Reset Method
Manual
Main Contact Tripping Mechanism Type
Trip free
Manual Actuator Type And Quantity
1 toggle
Actuator Function
Trip-reset
Actuator Position Designation
At pole two
Internal Trip Release Configuration
Series trip all locations
Trip Delay Time In Seconds Per Rated Continuous Current
0.500 at 200 pct all locations and 1.000 at 200 pct all locations
Inclosure Protection Type For Which Designed
Fungus resistant
Frequency In Hertz
60.0 all locations
Unpackaged Unit Weight
2.600 ounces
Terminal Type And Quantity
4 quick disconnect, male

Pricing and Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Qty:
Email Address:
Phone Number:
Your name:
Company:
Privacy    Terms

Certified Quality Assurance  Quality check icon

  •   ISO 9001:2015 + AS9120B
  •   Counterfeit Parts Prevention
  •   100% Product Inspections
  •   7 Year Record Retention
  •   On Time Delivery
  •   HAZMAT Certified
  •   Worldwide Shipping
E122150203024 Cross Reference
  • 203-22-1-61-153-4-1-1