1. Home /
  2. FSC NSN Catalog /
  3. Switches /
  4. MS25125-E3

NSN MS25125-E3

Toggle Switch

A shaped metallic item designed to increase the effectiveness of radio frequency/electromagnetic interference, or a nonmetallic item containing a wire mesh, metal, or other electrically conductive particles designed to provide environmental sealing and radio frequency/electromagnetic interference shielding. For bulk items see wire mesh, knitted or gasketing material, conductive.

1.082 inches nominal actuator height, 0.430 inches nominal actuator diameter, up position maintained and down position maintained actuator position-action relationship, up position no locking action and down position no locking action and center position locked out actuator position-locking relationship, round actuator style.

NSN 5930-00-923-6791 Datasheet

(NSN) National Stock Number
5930-00-923-6791
(FSC) Federal Supply Classification
5930 - Switches
(NIIN) National Item Identification Number
00-923-6791
Requires Demilitarization
Yes
(INC) Item Name Code
00184
Date
Thu, Jan 20, 1966
Schedule B Code
8536509065
Actuator Height
1.082 inches nominal
Actuator Diameter
0.430 inches nominal
Actuator Position-Action Relationship
up position maintained and down position maintained
Actuator Position-Locking Relationship
up position no locking action and down position no locking action and center position locked out
Actuator Style
round
Body Height
1.157 inches maximum
Body Length
1.157 inches maximum
Body Style
bushing mount
Body Width
0.641 inches maximum
Bushing Length
0.437 inches nominal
Contact Load Current Rating At Maximum Rated Voltage
20.000 amperes resistive dc and 15.000 amperes inductive dc and 5.000 amperes lamp dc and 10.000 amperes resistive ac and 10.000 amperes inductive ac and 3.000 amperes lamp ac
Features Provided
actuator seal
Inclosure Type
fully inclosed
Maximum Voltage Rating In Volts
115.0 ac and 28.0 dc
Mounting Method
threaded bushing
Mounting Surface To Terminal End Distance
1.125 inches maximum
Nominal Thread Size
0.469 inches
Nonpile-Up Contact Arrangement
1 pole, double throw, both positions maintained single switch unit
Overall Height
2.644 inches nominal
Overall Length
1.157 inches maximum
Overall Width
0.641 inches maximum
Specification/Standard Data
96906-ms25125 government standard
Terminal Type And Quantity
3 tab w/screw
Test Data Document
"81349-mil-dtl-83731 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Class
2a
Thread Quantity Per Inch
32
Thread Series Designator
uns

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000184

Cross Reference

CAGE Codes

31160
Datum Inc Bancomm-Timing Div
U.s./canadian manufacturers
03497
General Electric Co Outdoor Breaker Business Section
U.s./canadian manufacturers
71669
General Electric Co Switchgear and Control Division of Apparatus Group
U.s./canadian manufacturers
A00AM
E.c.a Etablissement Central des Approvisionnements des Forces Armees Royales
Military standards and standards organizations (ex:stanags,milspecs,defstans)
15605
Eaton Corp Opns & Technical Center
U.s./canadian manufacturers
81640
Safran Power Usa, Llc
U.s./canadian manufacturers
27192
Drs Naval Power Systems Inc Dba Drs Power & Control Technologies Inc
U.s./canadian manufacturers
88140
Eaton Corp Circuit Protective Devices Div Lincoln Plant
U.s./canadian manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)
96906
Military Standards Promulgated by Military Departments Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
72D - Communications/electronics, other than sigint/ew or comsec repair parts and components
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-50-9065
Description
switches, for a voltage not exceeding 1000 volts, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77255
(NAICS) North American Industrial Classification System
335931

Questions & Answers

  1. What is the FSCG of the NSN 5930-00-923-6791?

    The FSCG of the NSN 5930-00-923-6791 is 5930

  2. Does the NSN 5930-00-923-6791 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536509065

  3. Does NSN 5930-00-923-6791 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5930-00-923-6791 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5930-00-923-6791 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5930-00-923-6791 was assigned to the Federal Catalog?

    It was assigned 60 years ago, on Thu, Jan 20, 1966

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.