NSN SM3-20DC2

Circuit Breaker

A switch that is externally actuated by a device such as a push rod or button, which requires pushing for each actuation. The action may be momentary, with mechanical return. It consists of a body,switch and a push button. The item may include provisions for mounting indicating lamps or light emitting diodes in the actuator. Includes items consisting of individually separable switches that are physically interlocked, that have a common actuator, or are electrically connected. Excludes: light-switch; light-switch assembly; switch,beam selecting,headlight; switch,foot; switch,interlock; switch,pressure; switch,push-pull; switch,sensitive and switch assembly. For devices which start, stop, reverse, select and/or regulate the speed of a motor, see starter,motor and controller,motor.

1.562 inches maximum body length, magnetic blowout arc quenching method, at pole one actuator position designation, trip-reset actuator function, single pole type body style.

NSN 5925-00-929-7439 Datasheet

(NSN) National Stock Number
5925-00-929-7439
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
00-929-7439
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Wed, Sep 14, 1966
Schedule B Code
8536200040
Actuator Function
trip-reset
Actuator Position Designation
at pole one
Arc Quenching Method
magnetic blowout
Body Length
1.562 inches maximum
Body Style
single pole type
Body Width
0.625 inches maximum
Bushing Length
0.332 inches minimum and 0.380 inches maximum
Center To Center Distance Between Terminals Parallel To Length
0.906 inches maximum
Circuit Protection Type
overcurrent single location
Fragility Factor
moderately rugged
Inclosure Protection Type For Which Designed
fungus resistant and hermetically sealed
Internal Trip Release Configuration
series trip single location
Main Contact Tripping Mechanism Type
trip free
Manual Actuator Type And Quantity
1 toggle
Maximum Continuous Load Current Rating Per Pole
20.0 amperes dc single location
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
500.0 dc single location
Mounting Facility Type And Quantity
1 threaded bushing with panel seal
Mounting Surface To Terminal End Distance
1.700 inches maximum
Nominal Thread Size
0.375 inches
Operating Voltage Type And Rating Per Pole In Volts
50.0 dc single location
Pole Quantity
1
Reset Method
manual
Specification/Standard Data
81349-mil-c-39019/1 government specification
Storage Type
general purpose warehouse
Terminal Type And Quantity
2 wire hook
Test Data Document
"81349-mil-c-39019 specification (includes engineering type bulletins, brochures,etc., that reflect specification type data in specification format; excludes commercial catalogs, industry directories, and similar trade publications, reflecting general type data on certain environmental and performance requirements and test conditions that are shown as "typical", "average", "nominal", etc.)."
Thread Pitch Diameters
+0.3503 to 0.3537 inches
Thread Quantity Per Inch
32
Thread Series Designator
unef
Trip Delay Time In Seconds Per Rated Continuous Current
0.055 minimum at 200 pct and 0.950 maximum at 200 pct and 0.240 maximum at 400 pct single location
Trip Release Characteristic
time delay single location
Trip Release Method
magnetic single location
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
115.0 single location
Ultimate Trip Time Per Pole In Seconds
0.200 minimum and 7.000 maximum single location

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Source of Supply Code
S9E - Defense supply center columbus, columbus, oh 43218
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

94117
Bae Systems Information and Electronic Systems Integration Inc. Dba Bae Systems
U.s./canadian manufacturers
H0203
Thales Nederland
Non-us manufacturer (nato), other foreign organization or codification bureaus
81541
Sensata Technologies Maryland, Inc
Non-manufacturers
81349
Military Specifications Promulgated by Military Departments/agencies Under Authority of Defense Standardization Manual 4120 3-M
Military standards and standards organizations (ex:stanags,milspecs,defstans)
74193
Eaton Corp Heinemann Products Commercial Controls Div
U.s./canadian manufacturers

Freight Information

Air Commodity
HZ -
Air Dimension
A - Shipment is not a consolidation and does not exceed 84 inches in any dimension.
National Motor Freight Class Rating
M - 85.0
Special Handling
9 - Other or no special handling required (sh)
Type of Cargo
Z - No special type of cargo code applicable
Uniform Freight Classification Item Number
34430
Water Commodity
658 - Electrical appliances, small
National Motor Freight Classification Item Number
061360

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-00-929-7439?

    The FSCG of the NSN 5925-00-929-7439 is 5925

  2. Does the NSN 5925-00-929-7439 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-00-929-7439 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-00-929-7439 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-00-929-7439 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-00-929-7439 was assigned to the Federal Catalog?

    It was assigned 60 years ago, on Wed, Sep 14, 1966

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.

Recent Updates

Last Update: 1 day ago
View History