1. Home /
  2. FSC NSN Catalog /
  3. Circuit Breakers /
  4. THJ4V2602A

NSN THJ4V2602A

Circuit Breaker

A thin flat metal or plastic item of various peripheral shapes having a solid or laminated cross-section. It is designed to maintain a predetermined distance between two surfaces. For round items without a hole and having a solid rectangular cross-section use disk, solid, plain. Items with either (1) a solid (not laminated) cross-section, or (2) a non-separable laminated cross-section with one hole centrally located, must have a thickness less than 0.006 inch (0.152 mm) for items less than 1/4 inch (6.35 mm) outside diameter or shortest distance across peripheral flats, and less than 0.016 inch (0.406 mm) for items 1/4 inch (6.35 mm) or more outside diameter, or shortest distance across peripheral flats. For items with thickness greater than those indicated above, see spacer, plate; washer, flat and spacer, ring. When thickness and/or outside diameter or shortest distance across peripheral flats is designated as a tolerance dimension, the maximum dimension will be used to determine compliance. See also shim stock, laminated; shim stock assortment, gasket; and bearing, washer, thrust.

3.812 inches nominal body height, 10.125 inches nominal body length, 8.250 inches nominal body width, multipole-single actuator type body style, 0.500 inches nominal boss height.

NSN 5925-01-207-5008 Datasheet

(NSN) National Stock Number
5925-01-207-5008
(FSC) Federal Supply Classification
5925 - Circuit Breakers
(NIIN) National Item Identification Number
01-207-5008
Requires Demilitarization
Yes
(INC) Item Name Code
00136
Date
Thu, May 2, 1985
Schedule B Code
8536200040
Body Height
3.812 inches nominal
Body Length
10.125 inches nominal
Body Style
multipole-single actuator type
Body Width
8.250 inches nominal
Boss Height
0.500 inches nominal
Center To Center Distance Between Terminals Parallel To Length
9.120 inches nominal
Center To Center Distance Between Terminals Parallel To Width
2.750 inches nominal
Circuit Protection Type
undervoltage all locations
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length
7.875 inches nominal
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width
2.750 inches nominal
End Item Identification
used onboard 110 ft wpb coast guard vessels
Frequency In Hertz
60.0 all locations
Main Contact Tripping Mechanism Type
trip free
Material
plastic case
Maximum Continuous Load Current Rating Per Pole
200.0 amperes ac all locations
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps
220.0 ac all locations
Mounting Facility Type And Quantity
4 unthreaded hole(s)
Operating Voltage Type And Rating Per Pole In Volts
600.0 ac all locations
Pole Quantity
3
Reset Method
manual
Terminal Type And Quantity
6 compression
Trip Release Characteristic
instantaneous all locations
Trip Release Method
solid state all locations
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent
110.0 all locations
Ultimate Trip Time Per Pole In Seconds
3.000 nominal all locations
Unthreaded Mounting Hole Diameter
0.410 inches nominal

Identification

Demilitarization Code
A - Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.
Precious Metals Indicator
A - Item does not contain precious metal.
Hazardous Metals Indicator
P - Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.
Pseudo Item Name Code
0000136

Cross Reference

CAGE Codes

03497
General Electric Co Outdoor Breaker Business Section
U.s./canadian manufacturers

Freight Information

Schedule B & Trade

Schedule B
8536-20-0040
Description
automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi
End Use
20005 - Electric apparatus
Unit of Quantity
NO
USDA
Yes
(SITC) Standard International Trade Classification
77252
(NAICS) North American Industrial Classification System
335313

Questions & Answers

  1. What is the FSCG of the NSN 5925-01-207-5008?

    The FSCG of the NSN 5925-01-207-5008 is 5925

  2. Does the NSN 5925-01-207-5008 have a Schedule B code assigned?

    Yes, the Schedule B code is 8536200040

  3. Does NSN 5925-01-207-5008 require demilitarization?

    Items subject to the export administration regulations (ear) in parts 730-774 of title 15, code of federal regulations (cfr) (ccli or ear99) and determined by dod to present a low risk when released out of dod control. No demil, mut, or end use certificate is required. May require an export licensefrom doc.

  4. Does NSN 5925-01-207-5008 contain precious materials?

    Item does not contain precious metal.

  5. Does NSN 5925-01-207-5008 contain hazardous materials?

    Indicates there is no information in the hmirs. The nsn is in a fsc in table ii of fed std 313 and a msds may be required by the user. The requirement for a msds is dependent on a hazard determination of the supplier or the intended end use of item.

  6. When the NSN 5925-01-207-5008 was assigned to the Federal Catalog?

    It was assigned 41 years ago, on Thu, May 2, 1985

Globe Transparent
Get in Touch
Looking for technical parts, product details, or custom project planning? Our team has you covered with end-to-end support every step of the way.
Contact Us

Pricing & Availability

Send us a request for quote using the form below. Our team will contact you with an up to date pricing and availability quote ASAP.